Resultado da pesquisa (9)

Termo utilizado na pesquisa Larsson M.H.M.A.

#1 - Left atrial size and contractile function in healthy dogs and dogs with chronic mitral valve disease, 38(8):1622-1630

Abstract in English:

ABSTRACT.- Petrus L.C., Castro J.R., Mantovani M.M., Gimenes A.M., Duarte C.N., Goldfeder G.T., Schwartz D.S. & Larsson M.H.M.A. 2018. [Left atrial size and contractile function in healthy dogs and dogs with chronic mitral valve disease.] [Tamanho e função sistólica atrial esquerda em cães sadios e com doença valvar crônica de mitral.] Pesquisa Veterinária Brasileira 38(8):1622-1630. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Avenida Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com In humans, left atrial enlargement and reduced contractile functions are associated with adverse cardiovascular events and a poor prognosis in many dilatation of the left atrium occurs with the gradual evolution of chronic mitral valve disease and is well diseases. The left atrium is the most compromised cardiac chamber in dogs with chronic mitral valve disease (CMVD). Therefore, this study aimed to compare the main parameters of left atrial enlargement (left atrium/aorta ratio, left atrial diameter and volume indices) and contractile function (transmitral flow peak velocity A wave and time velocity integral, atrial fraction, and atrial ejection force) at different stages of valve disease, and correlate the left atrial diameter, volume, and contractile function indices with echocardiographic variables predictive of heart failure in dogs (transmitral flow peak velocity E wave, E wave/IVRT ratio, E wave/E´wave ratio, and E wave/A wave ratio). The results showed that progressive characterized by the left atrium/aorta ratio and left atrium volume index. The left atrial diameter and volume indices and left atrium/aorta ratio correlated positively with the transmitral flow peak velocity E wave and E wave/IVRT ratio, which are important indices of diastolic function. The left atrial contractile function indices increased as CMVD evolved. Except for the atrial fraction, the left atrial contractile function indices correlated with the left ventricular filling pressure indices.

Abstract in Portuguese:

RESUMO.- Petrus L.C., Castro J.R., Mantovani M.M., Gimenes A.M., Duarte C.N., Goldfeder G.T., Schwartz D.S. & Larsson M.H.M.A. 2018. [Left atrial size and contractile function in healthy dogs and dogs with chronic mitral valve disease.] [Tamanho e função sistólica atrial esquerda em cães sadios e com doença valvar crônica de mitral.] Pesquisa Veterinária Brasileira 38(8):1622-1630. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Avenida Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com O tamanho e a função atrial esquerda estão relacionados em humanos com eventos cardiovasculares adversos e prognóstico nas principais cardiopatias. Na doença valvar crônica de mitral (DVCM) em cães, o átrio esquerdo é a câmara cardíaca mais comprometida. Portanto, os objetivos deste estudo foram comparar os principais parâmetros de aumento atrial esquerdo (relação átrio esquerdo/aorta, índice do diâmetro atrial esquerdo e índice do volume atrial esquerdo) e função contrátil de átrio esquerdo (velocidade máxima e integral de velocidade da onda A do fluxo transvalvar mitral, fração atrial e força de ejeção atrial) nos diferentes estágios da doença valvar; correlacionar diâmetro e volume atrial esquerdo e os índices de função contrátil atrial esquerda com as variáveis ecocardiográficas preditivas de insuficiência cardíaca em cães (velocidade máxima da onda E do fluxo transvalvar mitral, relação E/TRIV, relação E/E’par e relação E/A). Os resultados mostraram que com a evolução progressiva da doença valvar crônica de mitral, ocorre dilatação progressiva do átrio esquerdo, bem caracterizada pela relação átrio esquerdo/aorta e pelo índice de volume atrial esquerdo. O índice do diâmetro atrial esquerdo, o índice de volume atrial esquerdo e a relação átrio esquerdo/aorta correlacionam-se, positivamente, com a velocidade da onda E e com a relação E/TRIV, que são importantes índices de função diastólica. Os índices de função contrátil do átrio esquerdo aumentam à medida que a DVCM evolui. Os índices de função contrátil do átrio esquerdo apresentam correlação positiva com os índices de pressão de enchimento ventricular esquerdo, exceção feita à fração atrial.


#2 - Myocardial velocities obtained by pulsed tissue Doppler in English Cocker Spaniels with dilated cardiomyopathy and congestive heart failure, 36(9):851-856

Abstract in English:

ABSTRACT.- Pereira G.G., Goldfeder G.T., Yamaki F.L., Oliveira V.M.C. & Larsson M.H.M.A. 2016. Myocardial velocities obtained by pulsed tissue Doppler in English Cocker Spaniels with dilated cardiomyopathy and congestive heart failure. Pesquisa Veterinária Brasileira 36(9):851-856. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: ggpereira2002@yahoo.com.br Dilated cardiomyopathy (DCM) is characterized by systolic myocardial dysfunction which is identified by low myocardial velocities obtained by pulsed tissue Doppler (PTD). However, increased preload is known to increase myocardial velocities which could overestimate myocardial function and turn dysfunction characterization into a challenge in dogs with DCM and congestive heart failure. To test the hypothesis that increased preload could hamper identification of low myocardial velocities in dogs with DCM and congestive heart failure the present study prospectively evaluated 32 English Cocker Spaniel dogs, being 16 with clinical DCM and 16 healthy for control purpose. The PTD analysis of regional velocities were performed in both longitudinal and radial myocardial displacements and systolic (Sm), early (Em) and late diastolic (Am) velocities were obtained in left ventricular free wall (LVFW) and interventricular septum (IVS). Peak radial subendocardial and subepicardial Sm velocities were lower in DCM group compared to control (0.065±0.018 vs. 0.102±0.020m/s and 0.059±0.014 vs. 0.094±0.025m/s respectively; p<0.001). Peak longitudinal Sm velocities were lower in basal and medial portions of LVFW (0.093±0.034 vs. 0.155±0.034m/s and 0.091±0.033 vs. 0.134±0.037m/s respectively; p<0.001) and IVS (0.063±0.021 vs. 0.136±0.039 and 0.066±0.026 vs. 0.104±0.032m/s respectively; p<0.001). Most of diastolic velocities were not significantly different between groups, although advanced myocardial disease and dysfunction are expected in DCM group. Reduction in systolic basal and medial longitudinal myocardial velocities and in radial myocardial velocities was the most significant PTD findings. Increased preload did not represent a problem to evaluate systolic dysfunction by PTD in English Cocker Spaniels with DCM, but influence of preload on assessment of diastolic velocities should be better elucidated.

Abstract in Portuguese:

RESUMO.- Pereira G.G., Goldfeder G.T., Yamaki F.L., Oliveira V.M.C. & Larsson M.H.M.A. 2016. Myocardial velocities obtained by pulsed tissue Doppler in English Cocker Spaniels with dilated cardiomyopathy and congestive heart failure. [Velocidades miocárdicas obtidas por meio de Doppler tecidual pulsátil em cães da raça Cocker Spaniel Inglês com cardiomiopatia dilatada e insuficiência cardíaca congestiva.] Pesquisa Veterinária Brasileira 36(9):851-856. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: ggpereira2002@yahoo.com.br A cardiomiopatia dilatada (CMD) é caracterizada por disfunção miocárdica sistólica, a qual pode ser identificada pelas baixas velocidades miocárdicas obtidas por meio de Doppler tecidual pulsátil (DTP). Contudo, sabe-se que a elevada pré-carga aumenta as velocidades miocárdicas, o que poderia superestimar a função miocárdica e tornar desafiadora a caracterização da disfunção nos cães com CMD e insuficiência cardíaca congestiva. Para testar a hipótese de que a elevada pré-carga pode mascarar a identificação de baixas velocidades miocárdicas nos cães com CMD e insuficiência cardíaca congestiva, o presente estudo avaliou prospectivamente 32 cães da raça Cocker Spaniel Inglês, sendo 16 com manifestações clínicas de CMD e 16 hígidos para efeito de grupo controle. A análise DTP das velocidades regionais foi realizada tanto no deslocamento miocárdico longitudinal quanto radial e foram obtidas as velocidades sistólica (Sm), diastólica inicial (Em) e tardia (Am) na parede livre do ventrículo esquerdo (PLVE) e no septo interventricular (SIV). Os valores de Sm radial subendocárdicos e subepicárdicos foram menores no grupo CMD em comparação com o grupo controle (0,065±0,018 vs. 0,102±0,020m/s e 0,059±0,014 vs. 0,094±0,025m/s, respectivamente; p<0,001). Os valores de Sm longitudinais foram menores nas porções basal e intermediária da parede do ventrículo esquerdo (0,093±0,034 vs. 0,155±0,034m/s e 0,091±0,033 vs. 0,134±0,037m/s, respectivamente; p<0,001) e do septo interventricular (0,063±0,021 vs. 0,136±0,039 e 0,066±0,026 vs. 0,104±0,032m/s, respectivamente; p<0.001). A maioria dos índices diastólicos não apresentou diferença significativa entre os grupos, apesar de a doença miocárdica avançada e a disfunção serem esperadas no grupo CMD. A redução nas velocidades sistólicas longitudinais nos segmentos basais e intermediários e nas velocidades radiais representaram os achados mais relevantes no estudo com DTP. Nos cães da raça Cocker Spaniel Inglês com CMD e insuficiência cardíaca congestiva a pré-carga elevada não representou empecilho para a avaliação da disfunção sistólica por meio de DTP, porém a influência da pré-carga na avaliação das velocidades diastólicas deve ser mais bem investigada.


#3 - Sensitivity and specificity of electrocardiographic examination in detecting ventricular or atrial overloads in Persian cats with hypertrophic cardiomyopathy, 36(3):187-196

Abstract in English:

ABSTRACT.- Pellegrino A., Daniel A.G.T., Pessoa R., Guerra J.M., Lucca G.G., Goissis M.D., Freitas M.F., Cogliati B. & Larsson M.H.M.A. 2016. [Sensitivity and specificity of electrocardiographic examination in detecting ventricular or atrial overloads in Persian cats with hypertrophic cardiomyopathy.] Sensibilidade e especificidade do exame eletrocardiográfico na detecção de sobrecargas atriais e/ou ventriculares em gatos da raça Persa com cardiomiopatia hipertrófica. Pesquisa Veterinária Brasileira 36(3):187-196. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: arinepel@yahoo.com.br Hypertrophic cardiomyopathy (HCM) is the most common feline heart disease and is characterized by increased cardiac mass with a hypertrophied and not dilated left ventricle. The echocardiography is the best noninvasive diagnostic tool for the differentiation of cardiomyopathies and is considered the gold standard for detection of ventricular hypertrophy present in HCM. Electrocardiographic changes are also common in animals with HCM and the electrocardiogram (ECG) is quick, easy and highly available screening test for the detection of ventricular hypertrophy in humans. In cats, few studies have been conducted regarding the sensitivity and specificity of ECG in detecting ventricular hypertrophy. With the intention of evaluating the use of ECG as a screening tool for diagnosis of HCM in cats, Persian cats (n=82) were evaluated by echocardiographic and electrocardiographic examinations. Animals with blocks and/or conduction disturbances were excluded from statistical analysis (n=22). Subsequently the animals included were classified as normal (n=38), suspicious (n=6) and affected by HCM (n=16). Statistical differences were observed in the P-wave amplitude in DII and R-wave amplitude in DII, CV6LL and CV6LU, with higher values in animals with HCM. Velocities and pressure gradient of aortic flow, left atrial diameter (LA) and LA/Ao ratio were higher in cats with HCM. Among the animals with ECG changes suggestive of left atrial enlargement (n=7), only two actually had LA enlargement on echocardiography, and among animals with left atrial enlargement on echocardiogram (n=7), only two had ECG changes suggestive of overload AE (40,4% of sensibility and 90,9% of specificity). Among the animals with ECG changes suggestive of left ventricular hypertrophy (n=6), five actually had ventricular hypertrophy on echocardiography, and among animals with HCM by echocardiography (n=16), only five showed electrocardiographic abnormalities suggestive of LV hypertrophy (31,25% of sensibility and 97,72% of specificity). We observed a positive correlation between diastolic thickness of the interventricular septum and/or left ventricular free wall and R-wave amplitude in DII and CV6LU. The electrocardiogram is quick and easy to perform, has good specificity in detecting ventricular hypertrophy in cats, however, has low sensitivity, with large numbers of false negative animals. Thus, the ECG assists in the diagnosis, but does not replace echocardiography in confirming ventricular hypertrophy.

Abstract in Portuguese:

RESUMO.- Pellegrino A., Daniel A.G.T., Pessoa R., Guerra J.M., Lucca G.G., Goissis M.D., Freitas M.F., Cogliati B. & Larsson M.H.M.A. 2016. [Sensitivity and specificity of electrocardiographic examination in detecting ventricular or atrial overloads in Persian cats with hypertrophic cardiomyopathy.] Sensibilidade e especificidade do exame eletrocardiográfico na detecção de sobrecargas atriais e/ou ventriculares em gatos da raça Persa com cardiomiopatia hipertrófica. Pesquisa Veterinária Brasileira 36(3):187-196. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: arinepel@yahoo.com.br A cardiomiopatia hipertrófica (CMH) é a principal cardiopatia dos felinos e é caracterizada por hipertrofia miocárdica concêntrica, sem dilatação ventricular. O ecocardiograma é o melhor meio diagnóstico não invasivo para a diferenciação das cardiomiopatias e é considerado padrão ouro para a detecção de hipertrofia ventricular presente na CMH. Alterações eletrocardiográficas também são comuns em animais com CMH e o eletrocardiograma (ECG) é um teste de triagem para detecção de hipertrofia ventricular em humanos, sendo um exame rápido e facilmente disponível. Em gatos, poucos estudos foram realizados quanto à sensibilidade e especificidade do ECG na detecção de hipertrofia ventricular. Com a intenção de avaliar o uso do ECG como ferramenta de triagem para diagnóstico de CMH em felinos, gatos da raça Persa (n=82) foram avaliados por meio de exames ecocardiográfico e eletrocardiográfico. Animais com bloqueios e/ou distúrbios de condução foram excluídos da análise estatística (n=22). Posteriormente, os animais incluídos foram classificados em: normais (n=38), suspeitos (n=6) e acometidos pela CMH (n=16). Observaram-se diferenças estatísticas na amplitude da onda P em DII e na amplitude de onda R em DII, CV6LL e CV6LU, com valores maiores nos animais com CMH; e nos valores ecocardiográficos de velocidade e gradiente de pressão do fluxo aórtico, diâmetro do átrio esquerdo (AE) e relação AE/Ao, com valores maiores nos gatos com CMH. Dentre os animais com alterações eletrocardiográficas sugestivas de sobrecarga atrial esquerda (n=7), apenas dois realmente apresentavam aumento do AE no ecocardiograma; e dentre os animais com aumento atrial esquerdo ao ecocardiograma (n=7), apenas dois apresentavam alterações eletrocardiográficas sugestivas de sobrecarga do AE (sensibilidade de 40,40% e especificidade de 90,90%). Dentre os gatos com alterações eletrocardiográficas sugestivas de sobrecarga ventricular esquerda (n=6), cinco realmente apresentavam hipertrofia ventricular ao ecocardiograma; e dentre os animais com CMH ao ecocardiograma (n=16), apenas cinco apresentaram alterações eletrocardiográficas sugestivas de sobrecarga do VE (sensibilidade de 31,25% e especificidade de 97,72%). Observou-se correlação positiva entre espessura diastólica do septo interventricular e/ou da parede livre do ventrículo esquerdo e a amplitude da onda R em derivações DII e CV6LU. O eletrocardiograma é um exame rápido e de fácil execução, apresenta boa especificidade na detecção de hipertrofia ventricular em felinos, porém, possui baixa sensibilidade, com grande número de falsos negativos. Desta forma, o ECG auxilia no diagnóstico, mas não substitui o ecocardiograma na confirmação da hipertrofia ventricular.


#4 - Serum dosage of CPK-MB in dogs with ST deviation by chemiluminescence, 34(Supl.1):74-78

Abstract in English:

ABSTRACT.- Santos A.L.F., Pereira G.G., Santos M.M., Gutierrez V.C.R., Calyjur P.C. & Larsson M.H.M.A. 2014. Serum dosage of CPK-MB in dogs with ST deviation by chemiluminescence. Pesquisa Veterinária Brasileira 34(Supl.1):74-78. Setor de Patologia Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: andrvet@usp.br Although frequently in humans, hypoxic and ischemic heart diseases are poorly documented in dogs, with only few reports of acute myocardial infarction (AMI) in this species. Some electrocardiographic findings might suggest myocardium hypoxia/ischemia, like ST segment elevation or depression, but there are no studies showing whether deviations in ST segment are associated to myocardial injury and serum increase of creatine phosphokinase (CPK-MB). In order to investigate possible myocardial cells injury in poor perfusion conditions, 38 dogs were studied, 20 with normal electrocardiogram and 18 with ST segment elevation or depression, recorded in lead II, at a paper speed of 50 mm/sec and N sensibility (1mV=1cm). Serum measurement of creatine phosphokinase isoenzyme MB (CPK-MB) in normal dogs (group 1) determined control values (in ng/mL), which were compared to those obtained from dogs with deviation (group 2), which allowed confirmation or not of myocardial injury. CPK-MB mean values obtained from dogs in groups 1 and 2 were 0.540ng/ml (SD±0.890)ng/mL and 0.440ng/mL (SD±1.106), respectively. At a significance level of 5%, the relation of CPK-MB with age, mass and total creatine phosphokinase (CPK-T) was not significant in groups 1 and 2. CPK-MB showed no difference, at 5% level, between groups 1 and 2. In conclusion, it is possible to use the human chemiluminescent immunometric assay kit in canine species and that hypoxia/ischemia revealed by ST segment deviation does not mean significant myocardium injury.

Abstract in Portuguese:

RESUMO.- Santos A.L.F., Pereira G.G., Santos M.M., Gutierrez V.C.R., Calyjur P.C. & Larsson M.H.M.A. 2014. Serum dosage of CPK-MB in dogs with ST deviation by chemiluminescence. [A dosagem sérica de CPK-MB em cães com desvio ST por quimiluminescência.] Pesquisa Veterinária Brasileira 34(Supl.1):74-78. Setor de Patologia Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: andrvet@usp.br Embora frequente em humanos, as doenças hipóxicas e isquêmicas do coração são pouco relatadas em cães, com poucos relatos de infarto agudo do miocárdio (IAM) nesta espécie. Alguns achados no eletrocardiograma podem sugerir hipóxia/isquemia miocárdica, como a elevação ou depressão do segmento ST, mas não há estudos que mostram se os desvios do segmento ST estão associados a lesões miocárdicas e aumento sérico da creatinafosfoquinase (CPK-MB). A fim de investigar possíveis lesões nas células miocárdicas em condições de má perfusão, 38 cães foram estudados, 20 com eletrocardiograma normal e 18 com elevação ou depressão do segmento ST, registrados em papel, na derivação II, velocidade de 50 mm/s e sensibilidade N (1mV = 1cm). A mensuração da creatinafosfoquinase isoenzima MB (CPK-MB) em cães normais (grupo 1) determinou os valores controle (em ng/ml), que foram comparados com os obtidos a partir de cães com desvio (grupo 2), permitindo a confirmação ou não da lesão miocárdica. Os valores médios de CPK-MB obtidos de cães nos grupos 1 e 2 foram 0,540ng/ml (DP±0,890) e 0,440ng / ml (DP ± 1.106), respectivamente. A um nível de significância de 5%, a relação de CPK-MB com a idade, massa e creatinofosfoquinase total (CPK-T) não foi significativa nos grupos 1 e 2. Não houve diferenças na CPK-MB, ao nível de 5%, entre os grupos 1 e 2. Conclui-se que é possível utilizar o kit de ensaio imunométrico por quimioluminescência humano na espécie canina e que a hipoxia/isquemia revelada pelos desvios do segmento ST, não significa lesão miocárdica.


#5 - Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation, 34(3):290-300

Abstract in English:

ABSTRACT.- Pellegrino A., Daniel A.G.T., Pereira G.G., Júnior F.F.L., Itikawa P.H. & Larsson M.H.M.A. 2014. [Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation.] Avaliação da função diastólica por meio de Doppler tecidual pulsado e colorido em gatos da raça Maine Coon geneticamente testados para a mutação no gene MyBPC-A31P. Pesquisa Veterinária Brasileira 34(3):290-300. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP, 05508-270, Brazil. E-mail: arinepel@yahoo.com.br Hypertrophic cardiomyopathy (HCM) is the most common feline heart disease and is characterized by increased cardiac mass with a hypertrophied nondilated left ventricle. Myocardial dysfunction occurs in cats with HCM but less is known about dysfunctions in initial stages of HCM. A mutation in MYBPC-A31P gene has been identified in a colony of Maine Coon cats with HCM. However, the close correlation between genotype and phenotype still be inconclusive. Myocardial analysis by tissue Doppler imaging (TDI) is a noninvasive echocardiographic method to assess systolic and diastolic function that is more sensitive than conventional echocardiography. To evaluate diastolic and systolic function in cats with mutation, with or without ventricular hypertrophy, Maine Coon cats (n=57) were screened for mutation and examined with both echocardiography and TDI (pulsed tissue Doppler and color tissue Doppler methods). Then, were phenotypically classified in: normal (n=45), suspects (n=7) and HCM group (n=5); and genotypically classified in: negative (n=28), heterozygous (n=26) and homozygous group (n=3). Myocardial velocities (by pulsed and color tissue Doppler imaging) measured in the basal and mildventricular segment of the interventricular septal wall (IVS), left ventricular free wall (LVW), left ventricular anterior wall (LVAW), left ventricular posterior wall (LVPW) and radial segment of LVW, was compared among different groups. A decreased longitudinal Em velocities (pulsed tissue Doppler) at the mildventricular segment of LVW was observed in HCM cats compared with suspects and normal cats. A decreased longitudinal Em/Am (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. A significant increased longitudinal E/Em (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. And a significant decreased longitudinal Sm (color tissue Doppler) at the basal segment of the LVW was observed in heterozygous cats compared with negative cats, both without hypertrophy. There was a positive correlation between summated early and late diastolic velocities (Em/Am) and heart rate; and a positive correlation between Sm and Em velocities and heart rate, both in pulsed and in color TDI. TDI analyses are a new, valuable and reproducible method in cats that alone is not able to identify cats with mutation before myocardial hypertrophy. Despite high expectations regarding the use of TDI for early identification of individuals with HCM, there is still need for larger studies with greater numbers of individuals.

Abstract in Portuguese:

RESUMO.- Pellegrino A., Daniel A.G.T., Pereira G.G., Júnior F.F.L., Itikawa P.H. & Larsson M.H.M.A. 2014. [Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation.] Avaliação da função diastólica por meio de Doppler tecidual pulsado e colorido em gatos da raça Maine Coon geneticamente testados para a mutação no gene MyBPC-A31P. Pesquisa Veterinária Brasileira 34(3):290-300. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP, 05508-270, Brazil. E-mail: arinepel@yahoo.com.br A cardiomiopatia hipertrófica (CMH) é a principal cardiopatia dos felinos e é caracterizada por hipertrofia miocárdica concêntrica, sem dilatação ventricular. Disfunções miocárdicas ocorrem em gatos com CMH, mas pouco se conhece a respeito destas alterações nos estágios iniciais da afecção. Em gatos da raça Maine Coon, a mutação no gene MyBPC-A31P está relacionada com a CMH de origem familial, porém, a correlação exata entre o genótipo e o fenótipo ainda é inconclusiva. A ecocardiografia tecidual é uma modalidade não invasiva que permite avaliação da função miocárdica e é mais sensível que a ecocardiografia convencional. Para avaliar as funções sistólica e diastólica, antes ou após a ocorrência de hipertrofia ventricular, gatos da raça Maine Coon (n=57), geneticamente testados para a mutação, foram avaliados por meio de ecocardiografias convencional e tecidual (nas modalidades Doppler tecidual pulsado e Doppler tecidual colorido). Posteriormente, foram fenotipicamente classificados em: normais (n=45), suspeitos (n=7) e acometidos pela CMH (n=5); e genotipicamente classificados em: negativos (n=28), heterozigotos (n=26) e homozigotos para a mutação (n=3). Valores de velocidades miocárdicas (Doppler tecidual pulsado e colorido) medidos na região basal e média do septo interventricular (SIV), da parede livre do ventrículo esquerdo (PVE), da parede anterior do ventrículo esquerdo (PAVE), da parede posterior do ventrículo esquerdo (PPVE) e do segmento radial da PVE, foram comparados nos diferentes grupos. Observou-se que as velocidades longitudinais Em (Doppler tecidual pulsado) na região média da PVE foram menores nos gatos com CMH quando comparados com suspeitos e normais. Os valores de Em/Am (Doppler tecidual colorido), na região basal do SIV, foram inferiores nos gatos com CMH quando comparados com suspeitos e normais. A relação E/Em (Doppler tecidual colorido), na região basal do SIV, foi maior nos gatos com CMH em relação aos suspeitos e normais, enquanto que os valores de Sm (Doppler tecidual colorido), em região basal da PVE, foram menores nos gatos heterozigotos quando comparados com os negativos, ambos sem hipertrofia ventricular. Observou-se correlação positiva entre a ocorrência de fusão das ondas Em e Am e a frequência cardíaca, assim como correlação positiva entre valores de Sm e Em e a frequência cardíaca (Doppler tecidual pulsado e colorido). A ecocardiografia tecidual é uma nova modalidade ecocardiográfica reprodutível em gatos que, isoladamente, não permite diferenciar gatos portadores da mutação antes do desenvolvimento de hipertrofia ventricular. Apresenta utilidade como auxílio no diagnóstico em fases iniciais, mas, apesar da expectativa para a identificação precoce de indivíduos portadores da CMH, ainda há necessidade de estudos mais extensos e com maior número de indivíduos.


#6 - Standardization of electrocardiographic parameters in healthy Golden Retrievers dogs, 30(12):1083-1088

Abstract in English:

ABSTRACT.- Pellegrino A., Yamaki F.L., Pereira R.C., Oliveira V.M. & Larsson M.H.M.A. 2010. [Standardization of electrocardiographic parameters in healthy Golden Retrievers dogs.] Padronização de parâmetros eletrocardiográficos de cães da raça Golden Retriever clinicamente sadios. Pesquisa Veterinária Brasileira 30(12):1083-1088. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: akaolar@usp.br The Duchenne’s muscular dystrophy (DMD) in humans is a X-linked neuromuscular disease, of recessive character, caused either by the absence or dysfunction of the dystrophin. Clinically, it is characterized by severe alteration in the skeletal musculature, resulting in precocious death. In Golden Retriever dogs, the mutation that takes to the muscular dystrophy happens spontaneously and the extensive homology among the pathogenesis of DMD and of Golden Retriever muscular dystrophy allows to qualify the dog as the main substitute of humans in the clinical tests of new therapies. The deficient myocardium in distrofin is more vulnerable to the pressure overload and the patients with DMD can develop dilated cardiomyopathy, arterial hypertension and the electrocardiogram can come distinctly abnormal. In the present study, 38 healthy Golden Retriever dogs were evaluated by electrocardiographic exam with the purpose to obtain parameters for the standardization of the electrocardiogram in the referred breed, what hereafter can serve as reference in the identification of bearer or affected dogs. Electrocardiographic values obtained were within normal values and reference for the various breeds of dogs, and the variables weight and age significantly altered heart rate and amplitude of the QRS complex.

Abstract in Portuguese:

RESUMO.- Pellegrino A., Yamaki F.L., Pereira R.C., Oliveira V.M. & Larsson M.H.M.A. 2010. [Standardization of electrocardiographic parameters in healthy Golden Retrievers dogs.] Padronização de parâmetros eletrocardiográficos de cães da raça Golden Retriever clinicamente sadios. Pesquisa Veterinária Brasileira 30(12):1083-1088. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: akaolar@usp.br A distrofia muscular de Duchenne (DMD) em humanos é uma alteração neuromuscular hereditária, de caráter recessivo, ligada ao cromossomo X e causada pela ausência ou disfunção da distrofina. Clinicamente, caracteriza-se por grave alteração na musculatura esquelética, resultando em morte precoce do indivíduo acometido. Em cães da raça Golden Retriever, a mutação que leva à distrofia muscular ocorre espontaneamente e a extensa homologia entre a patogênese da DMD e da distrofia muscular do Golden Retriever permite qualificar o cão como o principal substituto de humanos nos testes clínicos de novas terapias. O miocárdio deficiente em distrofina é mais vulnerável à sobrecarga de pressão e os pacientes com DMD podem desenvolver cardiomiopatia dilatada, hipertensão arterial e o eletrocardiograma pode se apresentar distintamente anormal. No presente estudo, foram avaliados exames eletrocardiográficos de 38 cães da raça Golden Retriever clinicamente sadios (20 animais de até 12 meses de idade e 18 animais entre 12 e 36 meses de idade), com a finalidade de se obter parâmetros para a padronização do eletrocardiograma nessa referida raça, o que futuramente poderá servir de referência na identificação de cães portadores ou afetados pela distrofia muscular. Os valores eletrocardiográficos obtidos encontraram-se dentro dos valores de normalidade e referência para as diferentes raças de cães; e as variáveis peso e idade alteraram significativamente a freqüência cardíaca e a amplitude do complexo QRS.


#7 - Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs, 30(7):586-592

Abstract in English:

ABSTRACT.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com This study evaluated aortic (AO) and pulmonary (Pul) valves flow with pulsed-wave Doppler by qualitative (presence of valvar insufficiency and characteristic of flow profile) and quantitative analysis, and the following echocardiographic parameters were obtained: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time. Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, thoracic radiography, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1.22±19.38m/s; AO MV= 0.72±0.08m/s; AO VTI= 0.14±0.02m; AO AT= 38.80±11.29ms; AO ET= 197.90±24.77ms; Pul PV= 0.95±0.18m/s; Pul MV= 0.63±0.10m/s; Pul VTI= 0.13±0.02m; Pul AT= 70.97±18.87ms; Pul ET= 203.70±28.98ms. Heart rate presented negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, Pul VTI, Pul ET, differently from the gender, that had no influence on the evaluated parameters. The comparison of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT.

Abstract in Portuguese:

RESUMO.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com Avaliaram-se com Doppler pulsátil os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), de 30 cães considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica. Obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,22±19,38m/s; V. Me. AO= 0,72±0,08m/s; VTI AO= 0,14±0,02m; TA AO= 38,80±11,29ms; TE AO= 197,90±24,77ms; V. Max. Pul= 0,95±0,18m/s; V. Me. Pul= 0,63±0,10m/s; VTI Pul= 0,13±0,02m; TA Pul= 70,97±18,87ms; TE Pul= 203,70± 28,98ms. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros apresentaram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul); outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VTI Pul, TE Pul,) e não se observou influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul.


#8 - Electrocardiographic evaluation in dogs submitted to right pneumonectomy, 29(8):599-604

Abstract in English:

ABSTRACT.- Irino E.T., Stopiglia A.J., Larsson M.H.M.A., Fantoni D.T., Aiello V.D., Kavhegian M.A.P., Simões E.A., Santos A.L.S. & Gama Filho H.A.N. 2009. [Electrocardiographic evaluation in dogs submitted to right pneumonectomy.] Avaliação eletrocardiográfica em cães submetidos à pneumonectomia direita. Pesquisa Veterinária Brasileira 29(8):599-604. Laboratório de Cirurgia Cardiotorácica, Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: stopa@usp.br The purpose for using lobectomy or pneumonectomy in dogs and cats, is to cure or palliate of bronchopulmonary diseases whenever conservative clinical treatment proves ineffective. Considering the marked changes caused by pneumonectomy, new experimental studies have to be done to assess the advantages of this surgical intervention allow its performance without any risk. The aim of the current study was to evaluate the electrocardiographic alterations in ten adult mongrel dogs of both sexes with between 10 and 30 Kg that were submitted to right pneumonectomy. The clinical parameters of the dogs were evaluated in a daily basis and the alterations in every electrocardiogram derivation were recorded. All dogs presented a good post-operative outcome. In most cases there were no electrocardiographic alterations; when these alterations were observed they were of no clinical significance and included premature ventricular complexes in one dog, most likely resulting from a cardiorespiratory arrest that was reverted to successfully, and a decreased width in the QRS complex amplitude on the first 0-14 days post surgery which returned to normal after sixty days post surgery.

Abstract in Portuguese:

RESUMO.- Irino E.T., Stopiglia A.J., Larsson M.H.M.A., Fantoni D.T., Aiello V.D., Kavhegian M.A.P., Simões E.A., Santos A.L.S. & Gama Filho H.A.N. 2009. [Electrocardiographic evaluation in dogs submitted to right pneumonectomy.] Avaliação eletrocardiográfica em cães submetidos à pneumonectomia direita. Pesquisa Veterinária Brasileira 29(8):599-604. Laboratório de Cirurgia Cardiotorácica, Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: stopa@usp.br O propósito das ressecções pulmonares em cães e gatos, quer sejam por lobectomia ou pneumonectomia, é a cura ou paliação de processos broncopulmonares sempre que os meios conservadores de tratamento clínico sejam considerados ineficientes. Tendo em vista as significativas alterações resultantes da pneumonectomia, novos estudos experimentais devem ser feitos para avaliar as vantagens dessa intervenção cirúrgica e determinar a maneira como aplicá-la com segurança. O presente estudo tem como objetivo avaliar as alterações eletrocardiográficas em dez cães adultos de ambos os sexos, sem raça definida, com 10-30 kg, submetidos à pneumonectomia direita. Foram avaliados diariamente os parâmetros clínicos de cada cão e as alterações em todas as derivações do eletrocardiograma. Todos os cães apresentaram um bom desenlace pós-operatório. Apenas um cão apresentou alteração de relevância clínica, um caso de complexos ventriculares prematuros, possivelmente decorrente da parada cardiorrespiratória, que foi revertido com sucesso. Houve diminuição da amplitude dos complexos QRS nos primeiros 14 dias, retornado ao normal após 60 dias de pós-operatório.


#9 - Evaluation of left ventricular diastolic echocardiographic parameters in healthy dogs by pulsed-wave Doppler, p.291-294

Abstract in English:

ABSTRACT.- Pereira G.G., Petrus L.C., Santos A.L.F., Yamaki F.L. & Larsson M.H.M.A. 2009. Evaluation of left ventricular diastolic echocardiographic parameters in healthy dogs by pulsed-wave Doppler. Pesquisa Veterinária Brasileira 29(4):291-294. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: ggpereira2002@yahoo.com.br Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E), peak A wave (peak A), E/A ratio (E/A), E wave deceleration time (EDT) and isovolumic relaxation time (IRVT) were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT), by age (peak A and E/A) and by body weight (TRIV). Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.

Abstract in Portuguese:

ABSTRACT.- Pereira G.G., Petrus L.C., Santos A.L.F., Yamaki F.L. & Larsson M.H.M.A. 2009. Evaluation of left ventricular diastolic echocardiographic parameters in healthy dogs by pulsed-wave Doppler. Pesquisa Veterinária Brasileira 29(4):291-294. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: ggpereira2002@yahoo.com.br Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E), peak A wave (peak A), E/A ratio (E/A), E wave deceleration time (EDT) and isovolumic relaxation time (IRVT) were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT), by age (peak A and E/A) and by body weight (TRIV). Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV